- Dataq Instrument Port Devices Driver Download For Windows
- Dataq Instrument Port Devices Driver Download For Windows 8.1
Reference Materials > Device Drivers and Device IDs | Previous | Next |
- Windows 7 drivers. Windows 7 is an operating system of Windows NT family which was released after Windows Vista but before Windows 8. According to the data on summer of 2017, Windows 7 is the most popular operating system in the world. According to the data on July, 2017, Windows 7 is used on 48.91% of all PCs worldwide.
- Provide an INF file that specifies the Ports device setup class and the Serial function driver as the service for the port. To configure a serial port as COM port, comply with the requirements that are defined in Configuration of COM Ports.
Windows Version | |||||||
Hardware | 95 | 98 | NT | ME | 2000 | XP, Vista | Vista, 7, 8, 10 |
All Serial Devices1 | N/A | Same as XP | N/A | It is not necessary to specify DeviceDriver for products using a physical COM port DeviceID = 'COMnn DeviceName BaudRate'2 nn=COM port number3 | |||
DI-145, DI-148, DI-149, DI-155, DI-158, DI-245, DI-710, DI-715B, and DI-718B USB versions1 | Only necessary with multiple devices DeviceID = 'COMnn DeviceName BaudRate'2 nn=COM port number3 | ||||||
DI-220, DI-221, and DI-222 | DeviceDriver = 'DI22nNT.DLL' DeviceID = n n = LPT# | ||||||
DI-1100 | N/A | DeviceDriver = 'DI30iNT.DLL' i = 07 DeviceID = 'nnnnnnnn' nnnnnnnn = the first 8 hexadecimal characters of the device serial number | |||||
DI-1110 | N/A | DeviceDriver = 'DI31iNT.DLL' i = 07 DeviceID = 'nnnnnnnn' nnnnnnnn = the first 8 hexadecimal characters of the device serial number | |||||
DI-1120 | N/A | DeviceDriver = 'DI33iNT.DLL' i = 07 DeviceID = 'nnnnnnnn' nnnnnnnn = the first 8 hexadecimal characters of the device serial number | |||||
DI-2008 | N/A | DeviceDriver = 'DI35iNT.DLL' i = 07 DeviceID = 'nnnnnnnn' nnnnnnnn = the first 8 hexadecimal characters of the device serial number | |||||
DI-2108 | N/A | DeviceDriver = 'DI32iNT.DLL' i = 07 DeviceID = 'nnnnnnnn' nnnnnnnn = the first 8 hexadecimal characters of the device serial number | |||||
DI-2108-P | N/A | DeviceDriver = 'DI34iNT.DLL' i = 07 DeviceID = 'nnnnnnnn' nnnnnnnn = the first eight hexadecimal characters of the device serial number | |||||
DI-4108, DI-4208, DI-4718B USB | N/A | DeviceDriver = 'DI36iNT.DLL' i = 07 DeviceID = 'nnnnnnnn' nnnnnnnn = the first 8 hexadecimal characters of the device serial number | |||||
DI-4108, DI-4208, DI-4718B Ethernet | N/A | DeviceDriver = 'DI37iNT.DLL' i = 07 DeviceID = Pointer to IP address or multiple IP addresses separated by commas (first item could be preceded by an unsigned 32-bit PublicKey for a ChannelStretch group and comma). WinDaq Dashboard uses the 32-bit time value in seconds since 1970 as a key. | |||||
DI-400, DI-401, and DI-410 | DeviceDriver = 'DI40nNT.DLL' DeviceID = n n=WinRT virtual device #4 | ||||||
DI-710, DI-715B, and DI-718B, and DI-718Bx Ethernet versions | DeviceDriver = 'DI6nnNT.DLL' nn =0 to 39 are reserved 40 to 69 for DI-710-E, DI-715B-E instruments 70-99 for DI-718B-E and DI-718Bx instruments5 DeviceID = IP address (example '192.168.1.0') or DeviceID = IP address:Port (for Remote Devices - example '192.168.1.0:10001') | ||||||
DI-720/730/740/760-EN | DeviceDriver = 'DI8nnNT.DLL' DeviceID = IP address (example '192.168.1.0') nn = the order of WinDaq/IP installation - look in c:windowstpdataq.ini | ||||||
DI-500/510/720/730/740/750/760-P | DeviceDriver = 'DI50nNT.DLL' DeviceID = n n = LPT# | Same as other systems for 32-bit versions, but N/A for 64-bit systems. | |||||
DI-720/730/740/760-USB | N/A | Same as XP | N/A | DeviceDriver = 'DI72nNT.DLL' n =DeviceID = USB ID of the device | |||
DI-700 | N/A | Same as XP | N/A | DeviceDriver = 'DI70nNT.DLL' n = DeviceID = USB ID of the device |
1The DI-145, DI-148U, DI-149, DI-155, DI-158U/UP, DI-245, and DI-71x USB versions all use a virtual COM port. Some products use a virtual COM port even though they may have an alternate interface connection (like USB). Such products use the serial port device driver and ID. For a list of devices using a Virtual COM Port see Virtual COM Ports.
2DeviceName = Model number of the device. BaudRate = the baud rate. For a listing of baud rates see Baud Rate. For Example: For a DI-158U installed at COM 2 with 38400 Baud the DeviceID = 'COM2 158 38400'; a DI-145 installed at COM 8 would be: 'COM8 145 4800'.
3As specified during installation of the device. COM port numbers of 01 to 99 are supported. Example: For a Serial device installed to COM 1 the DeviceDriver=DI101NT.DLL. Go to Virtual COM Ports for instructions on finding the correct COM port.
4Virtual Device # can be found in c:Windowstpdataq.ini, or at the end of the WinDaq installation.
5The order of WinDaq/IP installation - look in title bar of WinDaq Acquisition when running device or check your installation directory for file(s) named WDQDK6nn.EXE.
6Starting WinDaq acquisition with V3.89 or later sets DLLName= and DeviceID= in the TPDATAQ.INI [Global] section, which become the default DeviceDriver and DeviceID if not set by a program using WinDaq.ocx or DataqSdk.ocx.
7Or other digit if using multiple unsynchronized devices or synchronized groups.
Top
Find your product below.
Dataq Instrument Port Devices Driver Download For Windows
Some products use a virtual COM port even though they may have an alternate interface connection (like USB). Such products use the serial port device driver and ID. For a list of devices using a Virtual COM Port see Virtual COM Ports. 2 DeviceName = Model number of the device. BaudRate = the baud rate.
Universal WinDaq Software Installation* |
Includes support for all contemporary data acquisition hardware products that support WinDaq software. Installs drivers and WinDaq recording and playback software. Also includes optional Add-on software with a valid installation key. Download the Drivers ONLY. |
Windows Version | |||||||
Hardware | 95 | 98 | NT | ME | 2000 | XP, Vista | Vista, 7, 8, 10 |
All Serial Devices1 | N/A | Same as XP | N/A | It is not necessary to specify DeviceDriver for products using a physical COM port DeviceID = 'COMnn DeviceName BaudRate'2 nn=COM port number3 | |||
DI-145, DI-148, DI-149, DI-155, DI-158, DI-245, DI-710, DI-715B, and DI-718B USB versions1 | Only necessary with multiple devices DeviceID = 'COMnn DeviceName BaudRate'2 nn=COM port number3 | ||||||
DI-220, DI-221, and DI-222 | DeviceDriver = 'DI22nNT.DLL' DeviceID = n n = LPT# | ||||||
DI-1100 | N/A | DeviceDriver = 'DI30iNT.DLL' i = 07 DeviceID = 'nnnnnnnn' nnnnnnnn = the first 8 hexadecimal characters of the device serial number | |||||
DI-1110 | N/A | DeviceDriver = 'DI31iNT.DLL' i = 07 DeviceID = 'nnnnnnnn' nnnnnnnn = the first 8 hexadecimal characters of the device serial number | |||||
DI-1120 | N/A | DeviceDriver = 'DI33iNT.DLL' i = 07 DeviceID = 'nnnnnnnn' nnnnnnnn = the first 8 hexadecimal characters of the device serial number | |||||
DI-2008 | N/A | DeviceDriver = 'DI35iNT.DLL' i = 07 DeviceID = 'nnnnnnnn' nnnnnnnn = the first 8 hexadecimal characters of the device serial number | |||||
DI-2108 | N/A | DeviceDriver = 'DI32iNT.DLL' i = 07 DeviceID = 'nnnnnnnn' nnnnnnnn = the first 8 hexadecimal characters of the device serial number | |||||
DI-2108-P | N/A | DeviceDriver = 'DI34iNT.DLL' i = 07 DeviceID = 'nnnnnnnn' nnnnnnnn = the first eight hexadecimal characters of the device serial number | |||||
DI-4108, DI-4208, DI-4718B USB | N/A | DeviceDriver = 'DI36iNT.DLL' i = 07 DeviceID = 'nnnnnnnn' nnnnnnnn = the first 8 hexadecimal characters of the device serial number | |||||
DI-4108, DI-4208, DI-4718B Ethernet | N/A | DeviceDriver = 'DI37iNT.DLL' i = 07 DeviceID = Pointer to IP address or multiple IP addresses separated by commas (first item could be preceded by an unsigned 32-bit PublicKey for a ChannelStretch group and comma). WinDaq Dashboard uses the 32-bit time value in seconds since 1970 as a key. | |||||
DI-400, DI-401, and DI-410 | DeviceDriver = 'DI40nNT.DLL' DeviceID = n n=WinRT virtual device #4 | ||||||
DI-710, DI-715B, and DI-718B, and DI-718Bx Ethernet versions | DeviceDriver = 'DI6nnNT.DLL' nn =0 to 39 are reserved 40 to 69 for DI-710-E, DI-715B-E instruments 70-99 for DI-718B-E and DI-718Bx instruments5 DeviceID = IP address (example '192.168.1.0') or DeviceID = IP address:Port (for Remote Devices - example '192.168.1.0:10001') | ||||||
DI-720/730/740/760-EN | DeviceDriver = 'DI8nnNT.DLL' DeviceID = IP address (example '192.168.1.0') nn = the order of WinDaq/IP installation - look in c:windowstpdataq.ini | ||||||
DI-500/510/720/730/740/750/760-P | DeviceDriver = 'DI50nNT.DLL' DeviceID = n n = LPT# | Same as other systems for 32-bit versions, but N/A for 64-bit systems. | |||||
DI-720/730/740/760-USB | N/A | Same as XP | N/A | DeviceDriver = 'DI72nNT.DLL' n =DeviceID = USB ID of the device | |||
DI-700 | N/A | Same as XP | N/A | DeviceDriver = 'DI70nNT.DLL' n = DeviceID = USB ID of the device |
1The DI-145, DI-148U, DI-149, DI-155, DI-158U/UP, DI-245, and DI-71x USB versions all use a virtual COM port. Some products use a virtual COM port even though they may have an alternate interface connection (like USB). Such products use the serial port device driver and ID. For a list of devices using a Virtual COM Port see Virtual COM Ports.
2DeviceName = Model number of the device. BaudRate = the baud rate. For a listing of baud rates see Baud Rate. For Example: For a DI-158U installed at COM 2 with 38400 Baud the DeviceID = 'COM2 158 38400'; a DI-145 installed at COM 8 would be: 'COM8 145 4800'.
3As specified during installation of the device. COM port numbers of 01 to 99 are supported. Example: For a Serial device installed to COM 1 the DeviceDriver=DI101NT.DLL. Go to Virtual COM Ports for instructions on finding the correct COM port.
4Virtual Device # can be found in c:Windowstpdataq.ini, or at the end of the WinDaq installation.
5The order of WinDaq/IP installation - look in title bar of WinDaq Acquisition when running device or check your installation directory for file(s) named WDQDK6nn.EXE.
6Starting WinDaq acquisition with V3.89 or later sets DLLName= and DeviceID= in the TPDATAQ.INI [Global] section, which become the default DeviceDriver and DeviceID if not set by a program using WinDaq.ocx or DataqSdk.ocx.
7Or other digit if using multiple unsynchronized devices or synchronized groups.
Top
Find your product below.
Dataq Instrument Port Devices Driver Download For Windows
Some products use a virtual COM port even though they may have an alternate interface connection (like USB). Such products use the serial port device driver and ID. For a list of devices using a Virtual COM Port see Virtual COM Ports. 2 DeviceName = Model number of the device. BaudRate = the baud rate.
Universal WinDaq Software Installation* |
Includes support for all contemporary data acquisition hardware products that support WinDaq software. Installs drivers and WinDaq recording and playback software. Also includes optional Add-on software with a valid installation key. Download the Drivers ONLY. |
* Not compatible with: Windows XP, Vista, or special Windows 10S (Secure) version. Submit a Support Ticket for options.
Other Software
Dataq Instrument Port Devices Driver Download For Windows 8.1
Hardware model DI-159PLC Only | Hardware model DI-160 Only | Hardware model DI-161 Only |